 |
|
02-2057-3407
sales@konvision.co.kr
|
 |
 |
|
±¹¹ÎÀºÇà (KB) - (ÁÖ) ÄÁºñÁ¯
365237-01-000236
½ÅÇÑÀºÇà - (ÁÖ) ÄÁºñÁ¯
294-05-038917
¿ì¸®ÀºÇà - (ÁÖ) ÄÁºñÁ¯
203-381309-13-001
|
 |
|
|
Thermolyne¢â Premium Large Muffle Furnaces, Thermo Scientific Maker : Thermo Scientific/Barnstead Model : F6010 Power : AC220V,3Kw Max.Temp. : RT - 1200¡É Capacity 14L Dimensions (D x W x H) Interior10 x 12.8 x 6.8 in. (25 x 33 x 18cm) Dimensions (L x W x H) Exterior20.1 x 19.1 x 21 in. (51 x 48.5 x 53.3cm) Temperature Range (Metric)100¡Æ to 1200¡ÆC



Premium Large Muffle Furnaces, Thermo Scientific¢â Thermolyne Premium Large Muffle Furnace features a robust design and a choice of four temperature controller models, making it perfect for industrial applications. This furnace provides a spacious 14L (0.5 cu.ft.) capacity and reaches a maximum of 1200¡ÆC, making it ideal for ashing organic and inorganic samples and conducting gravimetric analysis. Four heating elements are located on the chamber top, bottom and sides for enhanced temperature uniformity Built-in vent port removes undesirable contaminants and moisture to extend the life of the element and unit Rear of the chamber incorporates a 0.95cm (0.38 inch) diameter port for monitoring chamber temperatures with independent measuring devices Optional stainless-steel shelf doubles load capacity (maximum temperature of 900¡ÆC) Door safety switch stops power to heating elements when door opens Thermocouple break protection cuts power to the heating elements, preventing a thermocouple failure runaway condition Furnaces with B1, C1, and D1 control also use a mechanical overtemperature protection relay Choice of Temperature Controllers Digital single setpoint control (A1): Single display shows actual temperature or setpoint Digital single setpoint control with single ramp to setpoint and a dwell (B1): Single display shows actual temperature or setpoint Digital programmable control with one stored program of eight segments (C1)
Digital programmable control with four stored programs, 16 segments per program (D1): Controller includes RS-232 communications
. »ó±â °¡°ÝÀº ¿î¼Ûºñ / ¼³Ä¡ºñ ¸¦ Æ÷ÇÔÇÏÁö ¾ÊÀº °¡°ÝÀÔ´Ï´Ù.
. Á¦Ç°¿¡ ´ëÇÑ »çÈİü¸®´Â ±âº»ÀûÀ¸·Î 2°³¿ùÀ̸ç Á¦Ç°ÆÇ¸Å½Ã »óÈ£ ÇùÀÇ °¡´É
ÇÕ´Ï´Ù.
. Á¦Ç°¿¡ ´ëÇÑ ÀÚ¼¼ÇÑ ¹®ÀÇ »çÇ×Àº
02-2057-3407, 042-826-3407 ·Î ¿¬¶ôÁֽñ⠹ٶø´Ï´Ù. |
|
|
ÆÇ¸Å¿Ï·á
|
ÆÇ¸Å ¿Ï·á
|
ÆÇ¸Å ¿Ï·á
|
ÆÇ¸Å¿Ï·á
|
ÆÇ¸Å¿Ï·á
|
 |
¹è¼Ûºñ : ±âº»¹è¼Û·á´Â ¹«·á ÀÔ´Ï´Ù. (µµ¼,»ê°£,¿ÀÁö ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù) 50,000,000¿ø ÀÌ»ó ±¸¸Å½Ã ¹«·á¹è¼ÛÀÔ´Ï´Ù. |
 |
º» »óǰÀÇ Æò±Õ ¹è¼ÛÀÏÀº ÀÏÀÔ´Ï´Ù.(ÀÔ±Ý È®ÀÎ ÈÄ) ¼³Ä¡ »óǰÀÇ °æ¿ì ´Ù¼Ò ´Ê¾îÁú¼ö ÀÖ½À´Ï´Ù.[¹è¼Û¿¹Á¤ÀÏÀº ÁÖ¹®½ÃÁ¡(ÁÖ¹®¼ø¼)¿¡ µû¸¥ À¯µ¿¼ºÀÌ ¹ß»ýÇϹǷΠÆò±Õ ¹è¼ÛÀϰú´Â Â÷À̰¡ ¹ß»ýÇÒ ¼ö ÀÖ½À´Ï´Ù.] |
 |
º» »óǰÀÇ ¹è¼Û °¡´ÉÀÏÀº ÀÏ ÀÔ´Ï´Ù.
¹è¼Û °¡´ÉÀÏÀ̶õ º» »óǰÀ» ÁÖ¹® ÇϽŠ°í°´´Ôµé²² »óǰ ¹è¼ÛÀÌ °¡´ÉÇÑ ±â°£À» ÀǹÌÇÕ´Ï´Ù. (´Ü, ¿¬ÈÞ ¹× °øÈÞÀÏÀº ±â°£ °è»ê½Ã Á¦¿ÜÇϸç Çö±Ý ÁÖ¹®ÀÏ °æ¿ì ÀÔ±ÝÀÏ ±âÁØ ÀÔ´Ï´Ù.) |
 |
»óǰ û¾àöȸ °¡´É±â°£Àº »óǰ ¼ö·ÉÀÏ·Î ºÎÅÍ ÀÏ À̳» ÀÔ´Ï´Ù. |
 |
»óǰ ÅÃ(tag)Á¦°Å ¶Ç´Â °³ºÀÀ¸·Î »óǰ °¡Ä¡ ÈÑ¼Õ ½Ã¿¡´Â ÀÏ À̳»¶óµµ ±³È¯ ¹× ¹ÝǰÀÌ ºÒ°¡´ÉÇÕ´Ï´Ù. |
 |
Àú´Ü°¡ »óǰ, ÀϺΠƯ°¡ »óǰÀº °í°´ º¯½É¿¡ ÀÇÇÑ ±³È¯, ¹ÝǰÀº °í°´²²¼ ¹è¼Ûºñ¸¦ ºÎ´ãÇÏ¼Å¾ß ÇÕ´Ï´Ù(Á¦Ç°ÀÇ ÇÏÀÚ,¹è¼Û¿À·ù´Â Á¦¿Ü) |
 |
ÀϺΠ»óǰÀº ½Å¸ðµ¨ Ãâ½Ã, ºÎǰ°¡°Ý º¯µ¿ µî Á¦Á¶»ç »çÁ¤À¸·Î °¡°ÝÀÌ º¯µ¿µÉ ¼ö ÀÖ½À´Ï´Ù. |
 |
½Å¹ßÀÇ °æ¿ì, ½Ç¿Ü¿¡¼ ÂøÈÇÏ¿´°Å³ª »ç¿ëÈçÀûÀÌ ÀÖ´Â °æ¿ì¿¡´Â ±³È¯/¹Ýǰ ±â°£³»¶óµµ ±³È¯ ¹× ¹ÝǰÀÌ ºÒ°¡´É ÇÕ´Ï´Ù. |
 |
¼öÁ¦È Áß °³º° ÁÖ¹®Á¦ÀÛ»óǰ(±Á³ôÀÌ,¹ßº¼,»çÀÌÁî º¯°æ)ÀÇ °æ¿ì¿¡´Â Á¦ÀÛ¿Ï·á, Àμö ÈÄ¿¡´Â ±³È¯/¹Ýǰ±â°£³»¶óµµ ±³È¯ ¹× ¹ÝǰÀÌ ºÒ°¡´É ÇÕ´Ï´Ù. |
 |
¼öÀÔ,¸íǰ Á¦Ç°ÀÇ °æ¿ì, Á¦Ç° ¹× º» »óǰÀÇ ¹Ú½º ÈѼÕ, ºÐ½Ç µîÀ¸·Î ÀÎÇÑ »óǰ °¡Ä¡ ÈÑ¼Õ ½Ã ±³È¯ ¹× ¹ÝǰÀÌ ºÒ°¡´É ÇÏ¿À´Ï, ¾çÇØ ¹Ù¶ø´Ï´Ù. |
 |
ÀϺΠƯ°¡ »óǰÀÇ °æ¿ì, Àμö ÈÄ¿¡´Â Á¦Ç° ÇÏÀÚ³ª ¿À¹è¼ÛÀÇ °æ¿ì¸¦ Á¦¿ÜÇÑ °í°´´ÔÀÇ ´Ü¼øº¯½É¿¡ ÀÇÇÑ ±³È¯, ¹ÝǰÀÌ ºÒ°¡´ÉÇÒ ¼ö ÀÖ»ç¿À´Ï, °¢ »óǰÀÇ »óǰ»ó¼¼Á¤º¸¸¦ ²À ÂüÁ¶ÇϽʽÿÀ. |
|
|
|