Measument Principle for SV series


The SV series has of 2 thin sensor plates thatare driven with electromagnetic force at the same frequency by vibrating at constant sine-wave vibration in reverse phase like a tuning- fork.

The electromagnetic drive controls the vibration of the sensor plates to keep in constant amplitude. The driving electric current, which is exciting force, will be detected as the magnitude of viscidity produced between the sensor plates and the sample fluid.


Sensor Unit

Corrosive-resistant gold-plate sensor plate and temperature sensor.


It is very important to measure the temperature of the fluid correctly because the viscosity is very much dependent upon the temperature of the fluid. SV series can detect accurate temperature immediately because the fluid and the detection unit (sensor plates) with small surface area/thermal capacity reach the thermal equilibrium in only a few seconds.


SV series, Tuning-fork Vibration Method does not cause damage to the sample fluid and allows measurement of cloud point of samples such as surface active agents and of surface/interface changes such as wettability because of its excellent feature for wide measurement range without the need to replace the sensor plates.



Display Unit

You can avoid unnecessary reading errors with easy-to-read, large, clear display: 13mm height for viscosity measurement and 11mm height for temperature measurement.



WinCT-Viscosity

WinCT-Viscosity (RsVisco) is software to import the measurements of viscosity and temperature from SV series to a PC automatically and display the measurement result by graph on real-time basis. The scaling function and the logarithm display is selectable in the function.

Saving the measurement data by ¡°CSV¡± file and opening it with the WinCT-Viscosity is very easy and convenient for your analysis of your sample fluid viscosity




Water Jacket

Our water jacket (AX-SV-37) (sold separately) used in conjunction with a commercially available constant heat water tank to heat the circulating system, ensures that the sample remains at a constant temperature and that the temperature can be changed for viscosity measurement.


(A small sample container AX-SV-34 and a glass container AX-SV-35 are available, sold separately.)




ÀúÁ¡µµ Á¡µµ°è ½Åǰ ÆÇ¸Å (SV-10)

BOX¸¸ °³ºÀÇÑ ½Åǰ(FULL SET)

ÆÇ¸Å°¡ : 450¸¸¿ø (ÀýÃæ°¡´É)


Ư¡

▪ ½Å¼ÓÇÑ ÃøÁ¤ÀÌ °¡´ÉÇÕ´Ï´Ù. (15ÃÊ)

▪ Ä¶¸®ºê·¹À̼Ç(Calibration) ±â´É ³»ÀåµÇ¾î ÀÖ½À´Ï´Ù.

  1 Point Calibration, 2 Point Calibration

▪ ÃøÁ¤ Á¤¹Ðµµ°¡ ¡¾1%·Î ¿ì¼öÇÕ´Ï´Ù.

▪ ¿Âµµµµ ÃøÁ¤ °¡´É ÇÕ´Ï´Ù. (0~100¡ÆC)

▪ ¼ÒÇÁÆ®¿þ¾î´Â ±âº»Á¦°ø ÀÔ´Ï´Ù.(WinCT-Viscosity)

▪ ½Ç½Ã°£À¸·Î Á¡µµ ÃøÁ¤ °¡´ÉÇÕ´Ï´Ù.

▪ °ÅǰÀÌ Æ÷ÇԵȠ½Ã·áµµ ÃøÁ¤ÀÌ °¡´ÉÇÕ´Ï´Ù.

▪ Á¹(Sol)¿¡¼­ °Ö(Gel) º¯È­µÇ´Â µ¥ÀÌÅÍ °üÂû °¡´ÉÇÕ´Ï´Ù.

▪ ÀϺ» JCSS (Japan Calibration Service System : ÀϺ»°è·®Ç¥ÁØ) Á¡µµ°è ºÐ¾ß È¹µæ  




¸ð µ¨ ¸í 

SV-10 

SV-100 

ÃøÁ¤¹æ½Ä 

Tuning Fork Vibration (À½Â÷ÇüÁøµ¿½Ä) 

ÃøÁ¤¹üÀ§ 

0.3 ~ 10,000 mPa.s 

1,000~ 100,000 mPa.s 

ÃøÁ¤´ÜÀ§ 

mPa.s, Pa.s, cP, P 

Pa.s, P 

°íÀ¯Áøµ¿¼ö 

30Hz 

ÃøÁ¤Á¤µµ (ÀçÇö¼º) 

1% (Full Range) 

ÀÛµ¿¿Âµµ 

10 ~ 40¡É 

1ȸ ÃøÁ¤½Ã »ùÇ÷® 

35 ~ 45ml 

½Ã·á¿ÂµµÃøÁ¤ºÎ 

0 ~ 100¡É/ 0.1¡É Ç¥½Ã 

Ç¥ ½Ã ºÎ 

VFD (Çü±¤Ç¥½Ã) 

Åë½Å±â´É 

RS-232C Ç¥Áس»Àå 

Àü ¿ø 

AC ¾Æ´äÅÍ (220V, 50Hz/60Hz, 17VA) 

¼³Ä¡È¯°æ 

20 ~ 30¡É, RH 45 ~ 60% 

Áß ·® 

ÃÑ 6.3Kg (ÃøÁ¤ºÎ 5.0Kg / Ç¥½ÃºÎ 1.3Kg) 

¿ÜÇü»çÀÌÁî 

ÃøÁ¤ºÎ : 332(W) x 314(D) x 536(H) 

Ç¥½ÃºÎ : 238(W) x 132(D) x 170(H) 

Ç¥ÁغμÓǰ 

Ãë±Þ¼³¸í¼­, AC ¾Æ´äÅÍ, CD-ROM(WinCT-Viscosity) 

Æú¸®Ä«º¸³×ÀÌÆ® »ùÇÿë±â, RS-232C ÄÉÀ̺í 



»óǰµî·Ï
¹è¼Ûºñ : ±âº»¹è¼Û·á´Â ¹«·á ÀÔ´Ï´Ù. (µµ¼­,»ê°£,¿ÀÁö ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù)  50,000,000¿ø ÀÌ»ó ±¸¸Å½Ã ¹«·á¹è¼ÛÀÔ´Ï´Ù.
º» »óǰÀÇ Æò±Õ ¹è¼ÛÀÏÀº ÀÏÀÔ´Ï´Ù.(ÀÔ±Ý È®ÀÎ ÈÄ) ¼³Ä¡ »óǰÀÇ °æ¿ì ´Ù¼Ò ´Ê¾îÁú¼ö ÀÖ½À´Ï´Ù.[¹è¼Û¿¹Á¤ÀÏÀº ÁÖ¹®½ÃÁ¡(ÁÖ¹®¼ø¼­)¿¡ µû¸¥ À¯µ¿¼ºÀÌ ¹ß»ýÇϹǷΠÆò±Õ ¹è¼ÛÀϰú´Â Â÷À̰¡ ¹ß»ýÇÒ ¼ö ÀÖ½À´Ï´Ù.]
º» »óǰÀÇ ¹è¼Û °¡´ÉÀÏÀº ÀÏ ÀÔ´Ï´Ù. ¹è¼Û °¡´ÉÀÏÀ̶õ º» »óǰÀ» ÁÖ¹® ÇϽŠ°í°´´Ôµé²² »óǰ ¹è¼ÛÀÌ °¡´ÉÇÑ ±â°£À» ÀǹÌÇÕ´Ï´Ù. (´Ü, ¿¬ÈÞ ¹× °øÈÞÀÏÀº ±â°£ °è»ê½Ã Á¦¿ÜÇϸç Çö±Ý ÁÖ¹®ÀÏ °æ¿ì ÀÔ±ÝÀÏ ±âÁØ ÀÔ´Ï´Ù.)
»óǰ û¾àöȸ °¡´É±â°£Àº »óǰ ¼ö·ÉÀÏ·Î ºÎÅÍ ÀÏ À̳» ÀÔ´Ï´Ù.
»óǰ ÅÃ(tag)Á¦°Å ¶Ç´Â °³ºÀÀ¸·Î »óǰ °¡Ä¡ ÈÑ¼Õ ½Ã¿¡´Â ÀÏ À̳»¶óµµ ±³È¯ ¹× ¹ÝǰÀÌ ºÒ°¡´ÉÇÕ´Ï´Ù.
Àú´Ü°¡ »óǰ, ÀϺΠƯ°¡ »óǰÀº °í°´ º¯½É¿¡ ÀÇÇÑ ±³È¯, ¹ÝǰÀº °í°´²²¼­ ¹è¼Ûºñ¸¦ ºÎ´ãÇÏ¼Å¾ß ÇÕ´Ï´Ù(Á¦Ç°ÀÇ ÇÏÀÚ,¹è¼Û¿À·ù´Â Á¦¿Ü)
ÀϺΠ»óǰÀº ½Å¸ðµ¨ Ãâ½Ã, ºÎǰ°¡°Ý º¯µ¿ µî Á¦Á¶»ç »çÁ¤À¸·Î °¡°ÝÀÌ º¯µ¿µÉ ¼ö ÀÖ½À´Ï´Ù.
½Å¹ßÀÇ °æ¿ì, ½Ç¿Ü¿¡¼­ ÂøÈ­ÇÏ¿´°Å³ª »ç¿ëÈçÀûÀÌ ÀÖ´Â °æ¿ì¿¡´Â ±³È¯/¹Ýǰ ±â°£³»¶óµµ ±³È¯ ¹× ¹ÝǰÀÌ ºÒ°¡´É ÇÕ´Ï´Ù.
¼öÁ¦È­ Áß °³º° ÁÖ¹®Á¦ÀÛ»óǰ(±Á³ôÀÌ,¹ßº¼,»çÀÌÁî º¯°æ)ÀÇ °æ¿ì¿¡´Â Á¦ÀÛ¿Ï·á, Àμö ÈÄ¿¡´Â ±³È¯/¹Ýǰ±â°£³»¶óµµ ±³È¯ ¹× ¹ÝǰÀÌ ºÒ°¡´É ÇÕ´Ï´Ù.
¼öÀÔ,¸íǰ Á¦Ç°ÀÇ °æ¿ì, Á¦Ç° ¹× º» »óǰÀÇ ¹Ú½º ÈѼÕ, ºÐ½Ç µîÀ¸·Î ÀÎÇÑ »óǰ °¡Ä¡ ÈÑ¼Õ ½Ã ±³È¯ ¹× ¹ÝǰÀÌ ºÒ°¡´É ÇÏ¿À´Ï, ¾çÇØ ¹Ù¶ø´Ï´Ù.
ÀϺΠƯ°¡ »óǰÀÇ °æ¿ì, Àμö ÈÄ¿¡´Â Á¦Ç° ÇÏÀÚ³ª ¿À¹è¼ÛÀÇ °æ¿ì¸¦ Á¦¿ÜÇÑ °í°´´ÔÀÇ ´Ü¼øº¯½É¿¡ ÀÇÇÑ ±³È¯, ¹ÝǰÀÌ ºÒ°¡´ÉÇÒ ¼ö ÀÖ»ç¿À´Ï, °¢ »óǰÀÇ »óǰ»ó¼¼Á¤º¸¸¦ ²À ÂüÁ¶ÇϽʽÿÀ.

ÁÖ¼Ò : °æ±âµµ °úõ½Ã »ïºÎ°ñ·Î51, 1Ãþ(Á־ϵ¿)
»ç¾÷ÀÚµî·Ï¹øÈ£ : 214-87-15796 | Åë½ÅÆÇ¸Å¾÷½Å°í¹øÈ£ : 2018-°æ±â°úõ-0002 |
°³ÀÎÁ¤º¸°ü¸®ÀÚ : ±èȸ¹ü | ´ëÇ¥ : ±èȸ¹ü | »óÈ£¸í : (ÁÖ)ÄÁºñÁ¯
ÀüÈ­¹øÈ£ : 02-2057-3407 | ÆÑ½º¹øÈ£ : 02-2057-3098 | ¸ÞÀÏ : sales@konvision.co.kr | È£½ºÆÃÁ¦°ø : (ÁÖ)°íµµ¼ÒÇÁÆ®
Copyright ¨Ï www.biokonvision.co.kr All right reserved